Troubleshooting
Tiling chapter of the Ditch Assist app manual. The same text is in the app under Manual.
In the app Manual › Tiling › Troubleshooting
"No tile design — Min Grade conflicts with depth window." Either lower Min Grade, raise Max Depth, or accept that the tile will hit the constraints. The design line still works — it just touches the limits.
The optimizer's Outlet is wrong. Tap the Outlet toggle in the dialog header to flip it.
Trench is too deep / too shallow at the outlet. The benchmark is off, or your Target Depth is wrong. Check the BM badge — should be green and showing a small offset. If unsure, drive to a point of known surface elevation and recalibrate.
Auto-Nudge controls don't appear. Correct — Tiling does not support Auto-Nudge. The toggle is forced off and the prompt is suppressed.
Tile depth fluctuates a lot in soft ground. The hydraulics can react too aggressively to GPS jitter. Open Settings → CONTROLLER and lower CRS values, or switch to Hold through the soft spot and run it manually for a few yards.
Did this answer your question?
Thanks. That tells us which pages to improve.
Still stuck? Talk to a product specialist. 1-833-DITCH-AS · support@ditchassist.com · Monday to Friday, 8 a.m.–5 p.m. Central.
Calling about a problem? Send your app logs first so support can see what happened.